---
title: How to install Cable Node Expander with EPIQ
description: How to install a Cable Node Expander with EPIQ
---

[Skip to content](https://knowledge.opisystems.com/en/knowledge/h#main-content)

English

Show submenu for translations

[Submit a support case to our team](https://knowledge.opisystems.com/en/knowledge/kb-tickets/new?hsLang=en)

![OPI\_with\_Tag\_RGB\_300dpi\_3in\_tall-1.png\]](https://knowledge.opisystems.com/hs-fs/hubfs/OPI_with_Tag_RGB_300dpi_3in_tall-1.png?height=50&name=OPI_with_Tag_RGB_300dpi_3in_tall-1.png)

Open main navigation

Close main navigation

- English
  
  Show submenu for translations
- [Submit a support case to our team](https://knowledge.opisystems.com/en/knowledge/kb-tickets/new)
- Visit OPIsystems

 Visit OPIsystems

 Hello. How can we help you?

- There are no suggestions because the search field is empty.

1. [OPIsystems Help Centre](https://knowledge.opisystems.com/en/knowledge?hsLang=en)
2. [EPIQ](https://knowledge.opisystems.com/en/knowledge/epiq?hsLang=en)

# How to install Cable Node Expander with EPIQ

## Cable Node Expanders are used in EPIQ to facilitate bins with large amounts of cables. Follow this guide to learn how to install

- Place the Cable Node Expander at the optimal installation location using the magnetic foot mount to secure it. Adjust the foot mount so it lines up where the bottom of the foot mount is aligned with the downward slope of the bin roof. You may secure the foot mount in place with a self-tapping screw; however, it is not necessary. The magnetic foot mount provides a secure installation without needing a self-tapping screw in most cases.

![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-08-26-1488-PM.png?width=378&height=532&name=image-png-Oct-26-2026-05-08-26-1488-PM.png)

- Once the Cable Node Expander is installed, open the lid of the node by unclipping the latch. Keep your hands and face clear of the Cable Node Expander as once the latch is unclipped the node will open on its own. The Cable Node Expander will remain open until you close it   
  ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-12-41-2206-PM.png?width=364&height=616&name=image-png-Oct-26-2026-05-12-41-2206-PM.png)
- Run the 3-wire cable up through the access port on the bottom of the Cable Node Expander. Once it is secure, establish a connection to the terminal on the Cable Node Expander circuit board.
- ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-15-27-9219-PM.png?width=559&height=619&name=image-png-Oct-26-2026-05-15-27-9219-PM.png)
- Close the lid and clip the latch back into place on the Cable Node Expander. Tighten to secure the access port on the bottom of the cable node expander board.
- Secure a 1’ length of 3-wire cable with a drip loop to the foot mount of the Cable Node Expander.   
  ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-16-59-7644-PM.png?width=301&height=400&name=image-png-Oct-26-2026-05-16-59-7644-PM.png)
- Run the 3-wire cable along the bin roof to the Primary/Secondary Node installation location, securing the wire with p-clips and self-tapping screws every 3’   
  ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-17-43-1395-PM.png?width=610&height=505&name=image-png-Oct-26-2026-05-17-43-1395-PM.png)
- Once the 3-wire cable reaches the Primary/Secondary Node, secure a 1’ length of communication cable with a drip loop to the foot mount of the Primary/Secondary Node.   
  ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-19-27-9982-PM.png?width=313&height=447&name=image-png-Oct-26-2026-05-19-27-9982-PM.png)
- Open the lid of the node by unclipping the latch. Keep your hands and face clear of the Primary/Secondary node as once the latch is unclipped the node will open on its own. The Primary/Secondary Node will remain open until you close it.   
  ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-20-00-0592-PM.png?width=355&height=466&name=image-png-Oct-26-2026-05-20-00-0592-PM.png)
- Run the other end of the 3-wire cable up through the access port on the bottom of the Primary/Secondary Node. Once it is secure, establish a connection to the terminal on the Primary/Secondary Node circuit board.   
  ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-21-39-9053-PM.png?width=406&height=469&name=image-png-Oct-26-2026-05-21-39-9053-PM.png)
- IN: Connection point for wire from Primary/ Secondary Node
- OUT: Connection point to additional expander or headspace sensor on last expander  
  ![](https://knowledge.opisystems.com/hs-fs/hubfs/image-png-Oct-26-2026-05-15-27-9219-PM.png?width=559&height=619&name=image-png-Oct-26-2026-05-15-27-9219-PM.png)
- Nodes can run on constant 12V line power, not just solar. This increases flexibility for larger sensor loads and supports indoor installations

- [OPIsystems Support](https://knowledge.opisystems.com/en/knowledge/opisystems-support?hsLang=en)
- [EPIQ](https://knowledge.opisystems.com/en/knowledge/epiq?hsLang=en)
- [OPI Blue](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#main-content)

    - [Upgrade Procedures](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#upgrade-procedures)
    - [Blue Seed](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#blue-seed)
    - [Cable Node](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#cable-node)
    - [agrimatics](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#agrimatics)
    - [Fan Node Radio (FNR)](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#fan-node-radio-fnr)
    - [Cell modem](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#cell-modem)
    - [Release Notes](https://knowledge.opisystems.com/en/knowledge/opi-blue?hsLang=en#release-notes)
- [BLUE Lite](https://knowledge.opisystems.com/en/knowledge/blue-lite?hsLang=en)
- [Integris](https://knowledge.opisystems.com/en/knowledge/integris?hsLang=en#main-content)

    - [bin file](https://knowledge.opisystems.com/en/knowledge/integris?hsLang=en#bin-file)
    - [Troubleshooting Information](https://knowledge.opisystems.com/en/knowledge/integris?hsLang=en#troubleshooting-information)
    - [Database](https://knowledge.opisystems.com/en/knowledge/integris?hsLang=en#database)
    - [Installation](https://knowledge.opisystems.com/en/knowledge/integris?hsLang=en#installation)
    - [Software](https://knowledge.opisystems.com/en/knowledge/integris?hsLang=en#software)
- [StorMax](https://knowledge.opisystems.com/en/knowledge/stormax?hsLang=en#main-content)

    - [Upgrade Procedures](https://knowledge.opisystems.com/en/knowledge/stormax?hsLang=en#upgrade-procedures)
    - [Update Information](https://knowledge.opisystems.com/en/knowledge/stormax?hsLang=en#update-information)
- [Upgrade Procedures](https://knowledge.opisystems.com/en/knowledge/upgrade-procedures?hsLang=en#main-content)

    - [RTU Upgrade](https://knowledge.opisystems.com/en/knowledge/upgrade-procedures?hsLang=en#rtu-upgrade)
- [Moisture Cable](https://knowledge.opisystems.com/en/knowledge/moisture-cable?hsLang=en)
- [Cable Node](https://knowledge.opisystems.com/en/knowledge/cable-node?hsLang=en)
- [OPI Blue Release Notes](https://knowledge.opisystems.com/en/knowledge/opi-blue-release-notes?hsLang=en#main-content)

    - [Gateway](https://knowledge.opisystems.com/en/knowledge/opi-blue-release-notes?hsLang=en#gateway)
    - [Cloud](https://knowledge.opisystems.com/en/knowledge/opi-blue-release-notes?hsLang=en#cloud)
    - [BLUE Lite](https://knowledge.opisystems.com/en/knowledge/opi-blue-release-notes?hsLang=en#blue-lite)
    - [EPIQ](https://knowledge.opisystems.com/en/knowledge/opi-blue-release-notes?hsLang=en#epiq)
- [Advanced Grain Management FAQs](https://knowledge.opisystems.com/en/knowledge/advanced-grain-management-faqs?hsLang=en)
- [Temperature Cable](https://knowledge.opisystems.com/en/knowledge/temperature-cable?hsLang=en)
- [Temperature/Moisture Cable](https://knowledge.opisystems.com/en/knowledge/temperature-moisture-cable?hsLang=en)
- [Plenum Pressure Sensor (PPOT)](https://knowledge.opisystems.com/en/knowledge/plenum-pressure-sensor-ppot?hsLang=en)
- [Install Guides](https://knowledge.opisystems.com/en/knowledge/install-guides?hsLang=en)
- [OPI Partner and Install Certification Information](https://knowledge.opisystems.com/en/knowledge/opi-partner-and-install-certification-information?hsLang=en)
- [OPIsystems Internal Knowledgebase](https://knowledge.opisystems.com/en/knowledge/opisystems-internal-knowledgebase?hsLang=en#main-content)

    - [Administration](https://knowledge.opisystems.com/en/knowledge/opisystems-internal-knowledgebase?hsLang=en#administration)
    - [Sales](https://knowledge.opisystems.com/en/knowledge/opisystems-internal-knowledgebase?hsLang=en#sales)
- [CO2 sensor](https://knowledge.opisystems.com/en/knowledge/co2-sensor?hsLang=en)
- [Fan Control](https://knowledge.opisystems.com/en/knowledge/fan-control?hsLang=en)
- [Warranty](https://knowledge.opisystems.com/en/knowledge/warranty?hsLang=en)

[![Chill listening crop-3](https://knowledge.opisystems.com/hs-fs/hubfs/OPI_with_Tag_RGB_300dpi_3in_tall-2.png?width=100&height=55&name=OPI_with_Tag_RGB_300dpi_3in_tall-2.png "Chill listening crop-3")](https://advancedgrainmanagement.com/)

Copyright © 2026, OPI