how do I set a Moisture Content (MC) offset value on a Stormax hand-held monitor?

This article will walk you through the necessary steps to set a moisture content offset value on a Stormax monitor

    • Since an offset value is to be set for a particular grain curve, go to the main (home screen) by turning off and on the monitor or by pressing the view button until on the home screen.
    • Once there, highlight the name of the "Customer" or the customer name option



    • Press "Menu" button
    • Select (highlight) "Grain Type" and press "ok" button



    • Once presented with the list of grain types, select (highlight) the curve to assign an offset different from 0 and press "page" button., then a new window will pop-up explaining how to change that 0.0 offset:






      • Using left/right arrow for Integer numbers
      • Using Up/down arrows for decimal numbers, then


          • press "esc" button to accept and exit
          • You will be asked whether all cables in all groups are to be changed, select "yes" and press "ok" button


              Done!