how do I set a Moisture Content (MC) offset value on a Stormax hand-held monitor?
This article will walk you through the necessary steps to set a moisture content offset value on a Stormax monitor
- Since an offset value is to be set for a particular grain curve, go to the main (home screen) by turning off and on the monitor or by pressing the view button until on the home screen.
- Once there, highlight the name of the "Customer" or the customer name option
- Press "Menu" button
- Select (highlight) "Grain Type" and press "ok" button
- Once presented with the list of grain types, select (highlight) the curve to assign an offset different from 0 and press "page" button., then a new window will pop-up explaining how to change that 0.0 offset:
- Using left/right arrow for Integer numbers
- Using Up/down arrows for decimal numbers, then
- press "esc" button to accept and exit
- You will be asked whether all cables in all groups are to be changed, select "yes" and press "ok" button